CS4MXOperating Instructions
Sensitivity, ground eect & discriminationCIGARETTEPACKET5p COINRING PULLSCREWCAPNAILHORSESHOEMILKBOTTLETOPIGNORE (NO SOUND) POSITIVE SIGNAL (SOU
Warranty & ServiceYour CS4MX is guaranteed free of manufacturing defects as conrmed in our written warranty. Contact us if you have any concerns
C.SCOPE INTERNATIONAL LTDKINGSNORTH TECHNOLOGY PARKWOTTON ROAD ASHFORDKENT TN23 6LN UK Telephone: +44 (0)1233 629181Fax: +44 (0)1233 645897email:
2 1) On Off/ Sensitivity control 2) Ground Level control 3) Pinpoint/ Discrimination 1/ Discrimination 2 switch 4) All-Metal/ Discrimination Leve
3CS4MXThe CS4MX is a high performance metal detector operating on the ‘MOTION’ principle. This means that the search-head must be kept moving at a ste
4Follow these simple steps to start using the CS4MX within minutes:1) Insert the lower stem into the upper stem (rst press in the spring clip).2) Twi
1) On Off/Sensitivity control. Rotary control switches the detector on/off and adjusts the sensitivity. Ground containing mineralisation and some beac
6Assembling the CS4MXThe stem lock should be slackened to allow the lower stem to enter the upper stem section. The spring clip should be pressed in t
Belt mountingSqueeze the control box retaining clips together using your thumbs as shown in the photograph. The control box will now slide towards you
8On the majority of inland sites the ground control should be set to AUTO and the recommended sensitivity setting between 7-9 on the scale will give t
Searching.We recommend searching with a low level of discrimination (1-4 on DISC 1). At this setting the CS4MX will not react to small pieces of iron