NOTE:
With the 200 Mohm range, if the input is short circuited, the display will
read 1Mohm. This 1Mohm should be subtracted from the measured
results.
3.2.6. Capacitance
Range Resolution Accuracy (% reading + digits)
2nF 1pF ± (4.0% of rdg + 3 digits)
20nF 10pF ± (4.0% of rdg + 3 digits)
200nF 0.1nF ± (4.0% of rdg + 3 digits)
2µF 1nF ± (4.0% of rdg + 3 digits)
20µF 10nF ± (4.0% of rdg + 3 digits)
Overload Protection: 250V DC or rms AC
3.2.7. Diode
Range Resolution Function
1mV Display: reads approximate
forward voltage of diode
Overload Protection: 250V DC or rms AC
Forward DC current: approximate 1mA
Reverse DC voltage: approximate 2.8V
3.2.6. Continuity
Range Function
Built-in buzzer will sound, if resistance is less
than 70 ohms
Overload Protection: 250V DC or rms AC
Open circuit voltage: approximate 2.8V
3.2.9. Frequency
Range Resolution Accuracy (% reading + digits)
20kHz 10Hz ± (1.5% of rdg + 10 digits)
Overload Protection: 250V DC or rms AC
Sensitivity: 200mV rms and input no more 10V rms