37
APPLICATION EXAMPLES
1) BASIC WIRINGS OF A STAND ALONE DOOR LOCK
HAA2866
NOTE:
Connect the 1N4004 as close as possible to the lock in parallel with the lock power terminals of the
lock to absorb the back EMF to prevent it from damaging the keypad. The 1N4004 is not required
if the electric lock is AC operated.
To avoid Electro-Static-Discharge from interfering with the operation of the keypad, always ground
the (
-
) terminal of the keypad to earth.
Always connect DOOR SENSOR terminal to (
-
) ground if not used.