HAM263D
00 (10/10/2008) VELLEMAN
16
Format:
XXyyyyyy#
XX = 11 USER CODE 1 for arm/disarm control of part. 1
12 USER CODE 2 for arm/disarm control of part. 2
13 USER CODE 3 for arm/disarm control of the
whole system (partition 1 and 2)
yyyyyy = 4 to 6 digits
# = validation
e. Memorize frequently bypassed zones (“HOME” mode)
HOME mode is only available for use with USER CODE 3 (whole system). However, partitions
can be bypassed by bypassing the zones within the partition one by one.
Zone 8 (24 hour zone) is excluded from use in HOME mode
Format:
HOMEyyyyyy#
HOME Press HOME button on keypad
yyyyyy = List of zones to be enabled, sequential e.g. 245 to
bypass zones 2, 4 and 5
# = validation
To use the home mode, simply type USER CODE 3, and ; all programmed zones will
automatically be bypassed.
f. Keypad audible notification set-up
Some audible notification can be passed on to the keypad. This is the case for the exit and entry
delay, after an alarm condition and for each key button press.
Alarm conditions concerning battery low or AC power failure conditions are always ON.
Passing these notifications through to the keypad will not affect the beep settings on the master
control unit.
Note that confirmation beeps from the
-button and -button are always enabled.
14yyyy#
14 master code
yyyy = 4 digits: 0=beep disabled, 1=beep enabled (default)
digit 1 Beep for exit delay
digit 2 Beep for entry delay
digit 3 Beep after alarm condition
digit 4 Beep after each key button press
# = validation
g. Alarm detection response time
The default zone response time is set to 500ms. This setting can be adjusted independently per
zone, depending on the conditions in that zone.
The 8 digit code represents the 8 protection zones. The first digit is zone 1 and the last digit is
zone 8. By putting the timing codes into the specific digit to independently the desired response
time can be set.
15yyyyyyyy#
14 master code
yyyyyyyy = 8 digits, default setting = 3
1 25 ms
2 250 ms
3 500 ms
4 750 ms
# = validation
h. Reset system to default
To reset the system to its default values, enter code 2100#.
Except for the master code, all other values will be cleared or set to their default.