4. Operating Instructions
1. Hold the DVM321 in the area to be tested and allow adequate time for the readings to stabilize.
2. Press the function switch (fig. above #4) to select %RH, °C or °F. Set the MIN or MAX function (#3) if needed.
3. Read the measurement results.
Do not immerse the measuring head in liquid ; it is intended for use in air only.
Do not expose the humidity sensor to direct sunlight. Do not touch or manipulate the humidity sensor.
If the low battery indication appears, the battery is too weak for adequate measurements. Replace it.
For more info concerning this product, please visit our website www.velleman.eu.
The information in this manual is subject to change without prior notice.
DVM321 – DIGITALE VOCHTIGHEIDS- & TEMPERATUURMETER
1. Inleiding
Aan alle ingezetenen van de Europese Unie
Belangrijke milieu-informatie betreffende dit product
Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt weggeworpen,
dit toestel schade kan toebrengen aan het milieu.
Gooi dit toestel (en eventuele batterijen) niet bij het gewone huishoudelijke afval; het moet bij een
gespecialiseerd bedrijf terechtkomen voor recyclage.
U moet dit toestel naar uw verdeler of naar een lokaal recyclagepunt brengen.
Respecteer de plaatselijke milieuwetgeving.
Hebt u vragen, contacteer dan de plaatselijke autoriteiten inzake verwijdering.
Dank u voor uw aankoop! Lees deze handleiding aandachtig voor u uw DVM321 in gebruik neemt.
2. Specificaties
Uitlezing ......................................... LCD met achtergrondverlichting
Sensortype:
Vochtigheid.................................. precisie capaciteitssensor
Temperatuur................................ thermistor (meetkop) en type K thermokoppel
Meetbereik:
Vochtigheid.................................. 0%RH ~ 100%RH
Temperatuur................................ -20°C ~ 60°C (-4 ~ 140°F)
Nauwkeurigheid:
bereik 5% ~95% RH .................... ± 3.5% RH (bij 23°C ±)
bereik -20°C ~ 60°C.................... ± 2.5°C
bereik -4°F ~ 140°F..................... ± 3.5°F
Responstijd .................................... 180s
Bemonstering................................. 2.5 keer per seconde
Polariteit ......................................... automatisch, met negatieve polariteitaanduiding (-)
Overbelasting................................. "OL"-weergave
Resolutie ........................................ 0.1% RH, 0.1°C / 0.1°F
Bedrijfscondities............................. 0°C ~ 50°C (32-122°F) ; < 80% RH niet condenserend
Opslagcondities.............................. -10°C ~ 60°C (14-140°F) ; < 80% RH niet condenserend
Automatische uitschakeling............ DVM312 schakelt zichzelf uit na ong. 15 minuten zonder bediening
Batterij............................................ 9V batterij