Velleman VMB1TSW User Manual

Browse online or download User Manual for Accessories for electrical Velleman VMB1TSW. Velleman VMB1TSW User Manual [en]

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - VMB1TSW

VMB1TSW Temperature sensor module for the Velbus system

Page 2

OVERVIEW HEATING INSTALLATION A heating installation usually consists of radiators or convectors, a boiler, circulation pump and a collector with va

Page 3 - CHARACTERISTICS

WIRING To interconnect the Velbus modules the use of twisted-pair cable (EIB 2x2x0.8mm2, UTP 8x0.51mm - CAT5 or equivalent) is recommended. When a l

Page 4

Relay cabinet wiring

Page 5 - VELBUS CHARACTERISTICS

Terminator Normally only 2 ‘TERM’ terminators must be used in a complete Velbus installation. Usually this will be on the end of 2 bus wires (for e

Page 6

Cooling or heating mode When the temperature sensor is configured to control an air-conditioning system, the frost flower LED (upper LED) will be li

Page 7 - OVERVIEW SENSOR MODULE

OPERATION Pushing the push button repeatedly will switch the module between anti-freeze, night, day or comfort mode successively. When the comfor

Page 8

SETTINGS Following parameters can be set via the temperature controller (see manual VMB1TC / VMB1TCW(W)) or via the Velbus link software:  the zone

Page 9

Minimum and maximum temperature The sensor records the minimum and maximum temperature. These values can be examined or reset via the temperature c

Page 10

CONFIGURING THE OUTPUTS The sensor module transmit messages over the Velbus when the status of one of its multiple outputs changes. Relay modules (

Page 11

REMOTE CONTROL The sensor module can be operated locally, but also remotely via a temperature controller VMB1TC / VMB1TCW(W) (refer to the manual o

Page 12 - Relay cabinet wiring

CONTENTS DESCRIPTION ...

Page 13 - Addressing

SWITCHING TO ANTI FREEZE MODE THROUGH WINDOW CONTACTS The heating can be switched automatically in anti freeze mode as soon as a window featuring wi

Page 14 - Cooling or heating mode

DIFFERENTIAL THERMOSTAT Using two sensors, a differential thermostat can be created. When the temperature difference between both sensors crosses a

Page 15 - OPERATION

The passage automatically 3° cooler than the office When the sensor module in the office is set to day-mode, the temperature in the passage must be

Page 16 - Time statistics

Passive cooling of a bedroom During summer time the bedroom is cooled via a fan that extracts air from a cooler room. Mount a temperature sensor in

Page 17 - Differential thermostat

Refer to our website for more information: www.velbus.be

Page 18 - CONFIGURING THE OUTPUTS

DESCRIPTION The sensor module can be used to measure and send temperatures over the Velbus-system. In combination with a relay module (VMB4RYNO / VM

Page 19 - REMOTE CONTROL

 Storage capacity of 10 different pushbuttons per control function  LED indications for:  thermostat function for cooling  comfort mode  day mode

Page 20 - - 0m 18

VELBUS CHARACTERISTICS  2-wire communication for Velbus data and 2 wires for power supply  data transmission: 16.6 Kbit/s  Serial data protoco

Page 21

 memory:  read  (over)write  set the status of the output LED  switching off the indication LED on the pushbutton module(s)  switch unjam fun

Page 22 - Passage

OVERVIEW SENSOR MODULE LED indication Settings 1 Cooling mode 8 Terminator 2 Comfort mode 3 Day mode 4 Night mode Wiring 5 Heating or a

Page 23 - Passive cooling of a bedroom

EMBEDDING THE TEMPERATURE SENSOR The temperature sensor VMB1TSW can be embedded in combination with blank frames VMBFBI and cover plate. It is possi

Page 24

EMBEDDING A TEMPERATURE SENSOR TOGETHER WITH A CONTROLLER The sensor (VMB1TSW) can be embedded together with a controller (VMB1TC / VMB1TCW) in a 4

Comments to this Manuals