VMB1TSW Temperature sensor module for the Velbus system
OVERVIEW HEATING INSTALLATION A heating installation usually consists of radiators or convectors, a boiler, circulation pump and a collector with va
WIRING To interconnect the Velbus modules the use of twisted-pair cable (EIB 2x2x0.8mm2, UTP 8x0.51mm - CAT5 or equivalent) is recommended. When a l
Relay cabinet wiring
Terminator Normally only 2 ‘TERM’ terminators must be used in a complete Velbus installation. Usually this will be on the end of 2 bus wires (for e
Cooling or heating mode When the temperature sensor is configured to control an air-conditioning system, the frost flower LED (upper LED) will be li
OPERATION Pushing the push button repeatedly will switch the module between anti-freeze, night, day or comfort mode successively. When the comfor
SETTINGS Following parameters can be set via the temperature controller (see manual VMB1TC / VMB1TCW(W)) or via the Velbus link software: the zone
Minimum and maximum temperature The sensor records the minimum and maximum temperature. These values can be examined or reset via the temperature c
CONFIGURING THE OUTPUTS The sensor module transmit messages over the Velbus when the status of one of its multiple outputs changes. Relay modules (
REMOTE CONTROL The sensor module can be operated locally, but also remotely via a temperature controller VMB1TC / VMB1TCW(W) (refer to the manual o
CONTENTS DESCRIPTION ...
SWITCHING TO ANTI FREEZE MODE THROUGH WINDOW CONTACTS The heating can be switched automatically in anti freeze mode as soon as a window featuring wi
DIFFERENTIAL THERMOSTAT Using two sensors, a differential thermostat can be created. When the temperature difference between both sensors crosses a
The passage automatically 3° cooler than the office When the sensor module in the office is set to day-mode, the temperature in the passage must be
Passive cooling of a bedroom During summer time the bedroom is cooled via a fan that extracts air from a cooler room. Mount a temperature sensor in
Refer to our website for more information: www.velbus.be
DESCRIPTION The sensor module can be used to measure and send temperatures over the Velbus-system. In combination with a relay module (VMB4RYNO / VM
Storage capacity of 10 different pushbuttons per control function LED indications for: thermostat function for cooling comfort mode day mode
VELBUS CHARACTERISTICS 2-wire communication for Velbus data and 2 wires for power supply data transmission: 16.6 Kbit/s Serial data protoco
memory: read (over)write set the status of the output LED switching off the indication LED on the pushbutton module(s) switch unjam fun
OVERVIEW SENSOR MODULE LED indication Settings 1 Cooling mode 8 Terminator 2 Comfort mode 3 Day mode 4 Night mode Wiring 5 Heating or a
EMBEDDING THE TEMPERATURE SENSOR The temperature sensor VMB1TSW can be embedded in combination with blank frames VMBFBI and cover plate. It is possi
EMBEDDING A TEMPERATURE SENSOR TOGETHER WITH A CONTROLLER The sensor (VMB1TSW) can be embedded together with a controller (VMB1TC / VMB1TCW) in a 4