Velleman VMB1TSW User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
VELBUS CHARACTERISTICS
2-wire communication for Velbus data and 2 wires for power supply
data transmission: 16.6 Kbit/s
Serial data protocol: CAN (Controller Area Network)
Short circuit proof (towards negative or positive pole of the power supply)
LED indication when receiving or transmitting data over the Velbus
bus error indication: 2 short flashes of the LEDs
auto recovering after 25 seconds when a bus error occurs
The sensor module can be given a designation with a maximum of 16 characters.
The temperature sensor module can transmit following messages:
output status
manual pushbutton status
sensor status
sensor temperature, minimum and maximum temperature
time statistics (heating/air-conditioning on time)
sensor settings
sensor configuration
module type (including zone number and software version)
sensor name
memory content
the communication error counter
The temperature sensor module can transmit following instructions:
change the status of the LED(s) on the pushbutton module
switching off the LED(s) on a pushbutton module
switching on the LED(s) on a pushbutton module
make LED(s) on a pushbutton module flash slowly
make LED(s) on a pushbutton module flash fast
the desired temperature for the linked sensor to create a differential thermostat
The temperature sensor module can receive following messages:
the status of a pushbutton module
The temperature sensor module can receive following instructions:
to set:
the desired temperature
the desired comfort temperature for heating
the desired day temperature for heating
the desired night temperature for heating
the anti-freeze safeguard temperature
the heating limit
the desired comfort temperature for cooling
the desired day temperature for cooling
the desired night temperature for cooling
the lower limit of the cooling preset range
the upper limit of the cooling preset range
the hysteresis
calibration of the sensor
the temperature difference for fast heating/cooling or for the differential thermostat
the temperature difference for fast heating or cooling
the alarm temperatures
the default duration of temporary mode (sleep time)
the zone number
the address of the linked sensor to set up a differential thermostat
to determine:
heating
cooling
local control panel:
lock
unlock
Page view 4