SPECIFICATIONS
Operating Voltage:
12V DC Nominal; 11-15V DC
Operating Current:
60mA (quiescent) to 95mA (two relays active)
Operation Temperature:
-20
C to +70
C
Environmental Humidity:
5-95% relative humidity non-condensing
Working Environment & Ingress Protection:
Indoor or Outdoor, IP-55 Weatherproof
Number of Users:
1,000 (PINs and/or Cards)
Proximity Card:
Standard EM Card or Keyfob, 125Khz
Number of Visitor Codes:
50, programmable for one time or with the time limit
Timings for Code Entry and Card Reading:
10 seconds waiting for next digit entry
30 seconds waiting for code entry after card reading
The Timer:
1-99,999 Seconds (Over 24 Hours possible) Programmable Timer for O/P 1
Egress Button:
Programmable for Instant, Delay with Warning and/or Alarm
Momentary or Holding Contact for the Exit Delay
Output Contact Ratings:
Output Relay 1 – N.C. & N.O. dry contacts, 2A/24VDC Max.
Door Bell Relay – N.O. dry contact, 1A/24VDC Max.
Tamper Switch – N.C. dry contact, 50mA/24VDC Max. , Magnet Operated Reed Switch
Dimensions:
168.5(H) X 46.5(W) X 24(D)mm
Weight:
160g net
Housing:
ABS Plastic Box